products centerproducts center

LXS Rotor-type signalling water meter

LXS Rotor-type signalling water meter

1. Appearance structure: The direct reading module is separated from the pulse sensing device type electronic remote water meter, connected with a short wire, and the wire is protected by a stainless steel hose.

2. Module protection level: lp68

3. Ambient temperature: -10~55C.

4. Internal battery life: 6 years or 50,000 pulses, whichever comes first (the large-caliber water meter should be equipped with an external power supply).


Download materials Return to list

2.jpg

Pulse constant:

It can be set to 100P/m3, 10P/m3, 1P/m3 according to user needs.

The recommended setting for DN25-DN50 is 10P/m3 and 1P/m3.

(The user can choose the appropriate pulse constant according to the diameter of the water meter and the supporting system. 1P/m3 means 1 pulse per cubic meter. The magnetic pointer is installed on the x0.1 pointer position. The following figure is only for position reference).

3.jpg

Transfer data:

1. Current cumulative water volume 2. Daily cumulative water volume 3. Internal fault alarm


5.jpg

6.jpg